NI 6509 User Guide and Specifications

20

ni.com

Power-on state ........................................Inputs high-Z (default),

user-selectable input,
output 1 or 0

Data transfers ..........................................Interrupts, programmed I/O

I/O connector ..........................................100-pin female 0.050 series SCSI

Digital Logic Levels

Input Signals

The maximum input logic high and output logic high voltages assume a
Vcc supply voltage of 5.0 V. Given a Vcc supply voltage of 5.0 V, the
absolute maximum voltage rating for each I/O line is –0.5 V to 5.5 V with
respect to GND.

Output Signals (Vcc = 5 V)

The total current sinking/sourcing from one port cannot exceed 100 mA.

+5V power available at
I/O connector (pins 49 and 99) ...............+4.65 to +5.25 V

Note

The I/O connector power has a fuse for overcurrent protection. This fuse is not

customer replaceable. If the fuse is blown, return the device to NI for repair.

Programmable power-up states
response time ..........................................400 ms

Level

Min

Max

Input voltage (V

I

)

0 V

Vcc

Input logic low voltage (V

IL

)

0.8 V

Input logic high voltage (V

IH

)

2 V

Level

Min

Max

High-level output current (I

OH

)

–24 mA

Low-level output current (I

OL

)

24 mA

Output voltage (V

O

)

0

Vcc

Output low voltage (V

OL

), at 24 mA

0.55 V

Output high voltage (V

OH

), at –24 mA

3.7 V