NI 9403 Operating Instructions and Specifications

12

ni.com

Timing

Input

Setup time

1

........................... 10 ns min

Hold time

2

............................ 60 ns min

Output

Propagation delay

3

............... 330 ns max

Channel-to-channel skew

4

... 265 ns max

1

Setup time is the amount of time input signals must be stable before reading from the

module.

2

Hold time is the amount of time input signals must be stable after initiating a read
from the module.

3

Propagation delay is the amount of time after writing to the module that the output
signals become valid.

4

Channel-to-channel skew is the amount of time between the first output signal
updating and the last output signal updating.