National Instruments NI 9403 User Manual

Page 13

Advertising
background image

© National Instruments Corp.

13

NI 9403 Operating Instructions and Specifications

Update/transfer time

1

cRIO-9151 R Series
Expansion chassis ................ 8

μS max

All other chassis................... 7

μS max

Direction change time

1

............... 18

μS max

Overvoltage protection
Channel-to-COM .............................. ±30 V max on up to

8 channels at a time;
however, continued use at
this level will degrade the life
of the module.

1

The update/transfer and direction change times are valid when the module is used in

a CompactRIO system. When used in other systems, driver software and system
latencies impact these times.