NI PCI-8254R Quick Start Guide

Caution

Do not connect the NI 8254R isolated power to a source less than 5 VDC or

greater than 30 VDC. Doing so could damage the NI 8254R device.

To connect power for the isolated outputs to the NI 8254R, refer to
Figures 2 through 6 while completing the following steps:

1.

If you are using the NI desktop power supply, remove the 4-position
power connector connected to the power supply, shown in Figure 2.

a.

Reconnect the wire that was connected to the V position on the
4-position power connector to the V position on the 2-position
isolated outputs power connector, shown in Figure 3.

b.

Reconnect the wire that was connected to the C position on the
4-position power connector to the C position on the 2-position
isolated outputs power connector, shown in Figure 3.

Figure 2. Removing the 4-Position Power Connector from the Power Supply

Figure 3. Connecting the 2-Position Power Connector to the Power Supply

2.

Plug the 2-position isolated outputs power connector from the power
supply into the power receptacle on the NI 8254R.

1

4-Position Power Connector

2

V Position

3

C Position

4

Power Supply Wire and Optional Ferrule

1

2-Position Isolated Outputs Power Connector

2

C Position

3

V Position

4

Power Supply Wire and Optional Ferrule

2

3

4

1

2

3

4

1