Connecting signal sources to the ni usb-9229/9239, Ni usb-9229/9239 circuitry – National Instruments NI USB-9229 User Manual

Page 11

Advertising
background image

© National Instruments Corporation

11

NI USB-9229/9239 User Guide and Specifications

Connecting Signal Sources to the NI USB-9229/9239

You can connect ground-referenced or floating signal sources to the
NI USB-9229/9239. If you make a ground-referenced connection between
the signal source and the NI USB-9229/9239, make sure the voltage on
the AI+ and AI– connections are in the channel-to-earth safety voltage
range to ensure proper operation of the NI USB-9229/9239. Refer to the

Specifications

section for more information about operating voltages and

overvoltage protection.

Figures 8 and 9 illustrate connecting grounded and floating signal sources
to the NI USB-9229/9239.

Figure 8. Connecting a Grounded Signal Source to the NI USB-9229/9239

Figure 9. Connecting a Floating Signal Source to the NI USB-9229/9239

NI USB-9229/9239 Circuitry

The NI USB-9229/9239 analog input channels are floating with respect to
earth ground and each other. The incoming analog signal on each channel
is conditioned, buffered, and then sampled by a 24-bit Delta-Sigma ADC.

NI USB-9229/9239

Signal

Source

AI–

+

AI+

NI USB-9229/9239

Signal

Source

AI–

+

AI+