Warning, Caution, A-12 / english – Nilfisk-Advance America Advenger BR 600S Series User Manual

Page 12: Operating the machine, Wet vacuuming

Advertising
background image

A-12 - FORM NO. 56041554 - Advenger

, Advenger

AXP / BR 600S series

A-12 / ENGLISH

OPERATING THE MACHINE

WARNING

!

Be sure you understand the operator controls and their functions.
While on ramps or inclines, avoid sudden stops when loaded. Avoid abrupt sharp turns. Use low speed down hills. Clean only
while ascending (driving up) the ramp.

To Scrub...
Follow the instructions in preparing the machine for use section of this manual.
1

While seated on the machine, adjust the seat and steering wheel to a comfortable operating position using the adjustment controls (25) and (5).

2

Turn the Master Key Switch (J) ON (I). This will display the control panel indicator lights, reference the Battery Condition Indicator (K) and Hour Meter
(G).

3

Release the Parking Brake (6). To transport the machine to the work area, apply even pressure with your foot on the front of the Drive Pedal (8) to go
forward or the rear of the pedal for reverse. Vary the pressure on the foot pedal to obtain the desired speed.

4

Adjust the Solution Flow Control Valve Lever (7) to about 1/4 to 1/3 open position (Non AXP/EDS models).

Press the Flow Rate Switch (T) to select a solution fl ow rate (AXP/EDS models).

The

fl ow rate can be changed to allow variable solution fl ow for different types of fl oors to be scrubbed. Example: A rough or absorbent fl oor surface

such as unfi nished concrete, will require more solution than a smooth fi nished fl oor.

NOTE (Non AXP/EDS Models): For a consistent reduced fl ow of solution; open the Solution Flow Control Valve Lever (7) all the way and then turn
ON the Smart Solutions™ / ECO Solution™ Valve (26). When the lever is in the “OFF” position; the machine operates conventionally; solution fl ow is
determined by the Solution Flow Control Lever (7). When the lever is in the “ON” position; solution fl ow is controlled automatically. The Solution Flow
Control Lever (7) should not be shut off, but is otherwise inactive. Make sure that the lever for Valve (26) is all the way ON or all the way OFF, never
in between. If more solution is needed, turn OFF the Smart Solutions™ / ECO Solution™ Valve (26) and adjust the solution fl ow with the Solution Flow
Control Valve Lever (7).
NOTE:
The solution, vacuum and detergent (AXP/EDS models) systems are automatically activated when the Scrub Pressure Decrease Switch (D)
or the Scrub Pressure Increase Switch (F) is pressed. No further action is required. Any individual system can be turned OFF or back ON by simply
pressing its switch at any time during scrubbing.

5

Press and hold the Solution Switch (R) for 5 seconds to pre-wet the fl oor. NOTE: This must be done prior to pressing the Scrub ON Switch (F).

6

When the Scrub Pressure Decrease Switch (D) or the Scrub Pressure Increase Switch (F) is selected, the brushes and squeegee are automatically
lowered to the fl oor. The machine’s scrub brush rotation, solution system fl ow, vacuum and detergent (AXP/EDS models) starts when the Drive
Pedal (8) is activated. Note: When operating the machine in reverse, only the brushes will rotate, the solution and detergent (AXP/EDS models) is
automatically shut off to conserve usage.

7

Begin scrubbing by driving the machine forward in a straight line at a normal walking speed and overlap each path by 2-3 inches (50-75 mm). Adjust
when necessary the machine speed and solution fl ow according to the condition of the fl oor.

CAUTION

!

To avoid damaging the fl oor, keep the machine moving while the brushes are turning.

8

When scrubbing, check behind the machine occasionally to see that all of the waste water is being picked up. If there is water trailing the machine, you
may be dispensing too much solution, the recovery tank may be full, or the squeegee tool may require adjustment.

9

For extremely dirty fl oors, a one-pass scrubbing operation may not be satisfactory and a “double-scrub” operation may be required. This operation is
the same as a one-pass scrubbing except on the fi rst pass the squeegee is in the up position (press the Vacuum Switch (O) to raise the squeegee).
This allows the cleaning solution to remain on the fl oor to work longer. The fi nal pass is made over the same area, with the squeegee lowered to pick
up the accumulated solution.

10 The recovery tank has an automatic fl oat shut-off to prevent solution from entering the vacuum system when the recovery tank is full. When the fl oat

shut-off is activated, the control system will shut down the scrub, vacuum, solution and detergent (AXP/EDS models) systems. The Scrub Pressure /
Hourmeter Display (G) will display “FULL”. To clear the display, press the Scrub OFF Switch (B), Scrub Pressure Decrease Switch (D), Scrub Pressure
Increase Switch (F) or the Vacuum Switch (O). When the fl oat closes, the recovery tank must be emptied. The machine will not pick up water with
the fl oat closed. NOTE: If the control repeatedly gives a full indication when the tank is not full, the automatic shut-off feature can be disabled, have a
qualifi ed service technician refer to the service manual to perform this function.

11 When the operator wants to stop scrubbing or the recovery tank is full, press the Scrub OFF Switch (B) once. This will automatically stop the scrub

brushes and solution fl ow and the scrub deck will raise UP. NOTE: the vacuum/squeegee system will not be turned off when the switch is only pressed
once, this is to allow any remaining water to be picked up without turning the vacuum back on. Press the switch a second time and the squeegee will
raise and the vacuum will stop after a 10 second delay.

12 Drive the machine to a designated waste water “DISPOSAL SITE” and empty the recovery tank. To empty, pull the Drain Hose (21) from its rear

storage area, then remove the plug (hold the end of the hose above the water level in the tank to avoid sudden, uncontrolled fl ow of waste water). Refi ll
the solution tank and continue scrubbing.

WET VACUUMING

Steps to follow in fi tting the machine with optional attachments for wet vacuuming.
1

Disconnect the recovery hose from the squeegee. Connect the coupler and hose from the wand kit to the recovery hose.

2

Attach suitable wet pick-up tools to the hose. (An optional Wand Kit PN56314307 is available from Nilfi sk-Advance).

3

Turn the Master Key Switch (J) ON, next press the Wand Switch (I). The vacuum motor and pump will run continuously until the switch is pressed
again to turn them OFF. NOTE: If the control repeatedly gives a full indication when the tank is not full, the automatic shut-off feature can be disabled,
have a qualifi ed service technician perform this function.

revised 3/06

Advertising