Shunt calibration characteristics – National Instruments NI 9236 User Manual

Page 27

Advertising
background image

© National Instruments Corp.

27

NI 9235/9236

Shunt Calibration Characteristics

Shunt calibration accuracy

Resistance

NI 9235....................................... 50 k

Ω

NI 9236....................................... 100 k

Ω

Output value

NI 9235....................................... –599.28

μV/V

NI 9236....................................... –873.47

μV/V

Temperature drift .............................. 15 ppm/°C

Method.............................................. Shunt across completion

resistor

Measurement

Conditions

NI 9235

Percent of Reading

(Gain Error)

NI 9236

Percent of Reading

(Gain Error)

Typical (25 °C, ±5 °C)

0.09%

0.07%

Maximum (–40 to 70 °C)

0.22%

0.2%

Advertising
This manual is related to the following products: