15

STALE AIR

TO OUTSIDE

STALE AIR

FROM HOUSE

FRESH AIR

TO INSIDE

14

3

/

4

"

(375)

19"

(483)

*

All Duct Connections 6"(150mm)

FILTERS

*NOTE: Front clearance
of 25 inches (635 mm)
is recommended
for ser vicing unit.

MOTOR

31"

(787mm)

FRESH AIR

FROM OUTSIDE

DAMPER

DEFROST

PORT

CONDENSATE DRAINS

ENTHALPIC

CORE

BALANCING DAMPER

OPTIONS
99-104

Digital Electronic Timer - 20/40/60 min. (3 wire)

99-109

Air Sentry™ Air Quality Monitor designed to accept remotely
mounted Control Pad.

99-186

Weatherhoods, Two - 6” (150mm) c/w 1/4” (6mm) mesh
screen

WARRANTY
Units carry a 5 year warranty on the energy recovery core and replace-
ment parts.

ERVs are not recommended for regions where the design temperature is
below 25°F (-4°C)

TI-200ERVD

0904

Air Flo

w (cfm)

200ERVD FANCURVE

200

175

150

125

100

75

50

25

0

0.3

0.4

0.5

0.6

0.7

0.8

0.9

Static Pressure (in H2O)

1.0

HIGH SPEED

*

MEDIUM HIGH SPEED

MEDIUM SPEED

MEDIUM LOW SPEED

LOW SPEED

4

5

3

2

1

5

4

3

2

1

?

*

Manufacturers Data

All units conform to
CSA and UL standards.

Model 200ERVD

DIMENSIONS 200ERVD

inches (mm

)

PERFORMANCE

Net supply airflow in cfm (L/s) against external static pressure

E.S.P

cfm

L/s

@ 0.1” (25 Pa)

232

(109)

@ 0.2” (50 Pa)

223

(105)

@ 0.3” (75 Pa)

215

(102)

@ 0.4” (100 Pa)

195

(92)

@ 0.5” (125 Pa)

189

(89)

Sensible Effectiveness
@ 127 cfm (60 L/s)

(CSA C439M)

67%

Sensible Efficiency

32°F (0

O

C)

60%

Total Efficiency

55%

VAC @ 60HZ

120

WATTS / Low speed

87

ENGINEERING DATA

LATENT RECOVERY/MOISTURE TRANSFER CORE
The cross-flow energy recovery core transfers heat and water vapour
between the two airstreams. It is easily removed for cleaning or service.
MOTORS AND BLOWERS
Each air stream has one centrifugal blower driven by a common PSC motor.
5 speed fan operation. High speed - 120 VAC.
FILTERS
Washable air filters in exhaust and supply air streams.
MOUNTING THE ERV
Four threaded inserts at corners of case designed to accept four PVC rein-
forced polyester straps that are supplied with the unit.
DEFROST
Damper defrost system.
DEHUMIDISTAT
Adjustable internal dehumidistat.
CASE
Twenty gauge prepainted galvanized steel (G60) for superior corrosion resis-
tance. Insulated to prevent exterior condensation.
DRAIN CONNECTIONS
Two - 1/2” (12mm) O.D.
CONTROLS
ControlAir 15 - Standby/ON mode, 20 ON/ 40 OFF mode, Recirculation mode
(on compatible units), (each mode has 5 speeds). Control pad can be
removed from HRV and remotely mounted.

Weight 63 lbs. (28.7 kg)