Environmental, Shock and vibration, Safety – National Instruments CFP-CB-3 User Manual

Page 17

Advertising
background image

© National Instruments Corp.

17

cFP-CB-1/2/3/4

Caution

Improper wiring may defeat isolation barrier.

Environmental

Compact FieldPoint connector blocks are intended for indoor use
only. For outdoor use, the Compact FieldPoint system must be
mounted inside a sealed enclosure.

Operating temperature ...................... –40 to 70 °C

Storage temperature .......................... –55 to 85 °C

Humidity ........................................... 10 to 90% RH,

noncondensing

Maximum altitude............................. 2,000 m; at higher altitudes,

the isolation voltage ratings
must be lowered

Pollution Degree ............................... 2

Shock and Vibration

Operating vibration, random
(IEC 60068-2-64).............................. 10–500 Hz, 5 g

rms

Operating vibration, sinusoidal
(IEC 60068-2-6)................................ 10–500 Hz, 5 g

Operating shock
(IEC 60068-2-27).............................. 50 g, 3 ms half sine,

18 shocks at 6 orientations;
30 g, 11 ms half sine,
18 shocks at 6 orientations

Safety

This product is designed to meet the requirements of the following
standards of safety for electrical equipment for measurement,
control, and laboratory use:

IEC 61010-1, EN 61010-1

UL 61010-1, CSA 61010-1

Note

For UL and other safety certifications, refer to the

product label or visit

ni.com/certification

, search

by model number or product line, and click the
appropriate link in the Certification column.

Advertising