7

cFP-CB-1/2/3/4

Figure 9. NI 9940 Connector Backshell Installed on cFP-CB-2

Wiring to the cFP-CB-4

You need a flathead screwdriver with a blade smaller than
2.3 × 1.0 mm (0.09 × 0.04 in.) to connect wires to the detachable
screw-terminal connector. Complete the following steps:

1. Verify that there are no cuts in the wire insulation that can

cause a safety hazard.

2. Strip 9 mm (0.35 in.) of insulation from the ends of the wires.

3. Insert the entire stripped ends of the wires into the appropriate

screw terminals. Do not allow any bare wire to show outside
the screw terminals.

4. Tighten the screw terminals to 0.22–0.25 N

⋅ m

(1.9–2.2 lb

⋅ in.) of torque.

5. When the wiring is complete, insert the connector into the

cFP-CB-4 and tighten the screws on the ends of the connector.