Net Optics Director User Manual

Page 50

Advertising
background image

Director

46

Command Sub-Command Arguments

Example and description

image

< 1 | 2 >

image 2

Arguments:

Valid values are 1 and 2

Chooses which system image to boot from (see
upgrade command)

show

image show

Lists the names of both system images and indicates
which one is running, and which one is selected to
boot from (arrow next to image name)

list

list

Shows a list of filenames of saved Director device
configurations (see save command)

load

<filename>

load my_configuration-1

Arguments:

<filename> is the name of the file to load; a

string;

do not include an extension

Loads a previously saved Director configuration (see
save
command)

logout

logout

Exits the CLI shell (same as exit and quit)
Note: To maintain system security, control is not
returned to the command shell.

module

show

module show

Lists information about Director hardware modules
including system serial number, DNM types, and
XFPs

passwd

This
command
is only
available
at root
level

passwd

Interactively changes the password of the SSH user
account

ping

<address>

ping 10.1.1.4

Arguments:

<address> is an IP address

Pings the specified IP address to check for connectivity

port

set

ports=<portlist>
autoneg=< on | off >
duplex=< full | half >
speed=< 10 | 100 | 1000 >

port set n1.1-n1.3 autoneg=on duplex=full

Arguments:

<portllist> is a portlist
For other arguments, select a value from the
listed choices

For 10/100/100 Copper interface Network and Moni-
tor ports, enables or disables autonegotiation; selects
the duplex mode; and sets the fixed speed (10Mbps,
100Mbps, or 1000Mbps) if autonegotiation is off

show

port show

Displays the current port status and settings

Advertising