Important – NEC Server 140Rc-4 User Manual
Page 139
Advertising

Configuring Your Server 4-29
The table below shows the operation when the AC power to the server is turn off once and then on
again, depending on the setting of "AC-LINK."
Setting of AC-LINK
System status before AC power off
Stay Off
Last State
Power On
Operating
Off
On
On
Aborting (DC power being off also)
Off
Off
On
Forced shutdown
Off
Off
On
* Press the power switch continuously at least four seconds. This forcibly turns off the power.
IMPORTANT:
Set this item to "Power on" in order to link the AC
power source supplied from UPS when the server is connected to UPS.
Advertising
This manual is related to the following products: