Vpd-6830-xeq, Configuration – Nokia 6800 Series User Manual

Page 102

Advertising
background image

6800/7000 Series - Distribution and Routing Products Installation and Operation Manual

75

VPD-6830-XEQ

Chapter 8: VPD-6830 Programmable Video DA Series

VPD-6830-XEQ

Configuration

1. Set the Input Coupling for either AC or DC coupling using jumpers

J2

and J3. See Figure 8-7 on page 76 for jumper locations.

2. Set the Clamping mode on jumper J1 to either Soft, Hard or No

Clamp

. See Figure 8-7 on page 76 for jumper location.

3. Adjust the gain over a range of -3 dB to +3 dB using the R5

multi-turn potentiometer in the base module.

Turn the potentiometer clockwise to increase the gain. See
Figure 8-8 on page 76.

4. Adjust the equalization using the R6 multi-turn potentiometer in the

base module.

Turn the potentiometer clockwise to obtain more equalization. See
Figure 8-8 on page 76.

5. Make fine adjustments to the high-frequency response using the R21

single-turn potentiometer in the base module.

The high-frequency response is factory-set/calibrated.
Readjustment is not recommended without precise test equipment.
See Figure 8-8 on page 76.

6. Select the cable length range compensation with jumpers J1 and J2,

located on the VPD-SBEQ submodule. See Figure 8-7 on page 76.

The R6 equalization potentiometer
on the VEA-6840 (Figure 8-7) is
used for continuous equalization
adjustments from 0 to 1000 ft
(300 m).

Advertising