LED Indicators

LED

Name

Indication

D1 (Green)

Data Present

Data is present at the input.

D3 (Red)

No Data

No data is at the input.

D5 (Red)

No Locked

The input data cannot be locked
by the reclock stage.

D2 (Yellow)

143 MHz

The input data is re-locked on 143
MHz.

D4 (Yellow)

177 MHz

The input data is re-locked on 177
MHz.

D6 (Yellow)

270 MHz

The input data is re-locked on 270
MHz.

D7 (Yellow)

360 MHz

The input data is re-locked on 360
MHz.

D8 (Yellow)

540 MHz

The input data is re-locked on 540
MHz.