User interface, Indicators and controls – Nokia 6800 Series User Manual

Page 47

Advertising
background image

Chapter 2: DNH-6800 DigiNet Hub Module

User Interface

20

6800/7000 Series - Distribution and Routing Products Installation and Opertion Manual

User Interface

Indicators and Controls

The user interface consists of LEDs that indicate various states or
activities, a jumper for disabling Channel 0, and a Reset button. These
are described in the table below and shown in Figure 2-5 on page 21.

When a signal collision occurs,
the DNH-6800 briefly jams all
the nodes from transmitting.
The nodes then begin re-
transmitting the packets at
randomized intervals.

Indicators
and Controls

Function

Power LED

The green power LED indicates that the DNH-6800 is
powered on.

Channel LEDs

Each channel has a pair of LEDs, one green and one
red.

• The green LED lights when signal transmission is

occurring on that channel.

• The red LED briefly lights when a signal collision

occurs on that channel.

Jamming LED

The jamming process occurs in conjunction with the
collision detection feature and is indicated by a red
LED.

Channel 0 Disable
Jumper

Channel 0 is disabled with this jumper.

This allows each DNH-6800 module within a single
frame to act independently.

Configuration LED

In the event of a configuration failure, this LED
remains continuously lit.

Reset Button

The Reset button is used to reset the DNH-6800
module after a configuration failure.

Advertising