5

Error Detection and Reporting

Chapter 1: AES-6880 AES/EBU Digital Audio Distribution Amplifier Module

Error Detection and Reporting

The AES-6880 DA constantly monitors the incoming AES data stream
and reports the following error conditions via the LED indicators
mounted near the card’s front edge. LED indicators and conditions are
described in the following table:

Condition

Indicator

Description Of Condition

All OK;
No Errors

Green LED

No errors detected.

No Lock

Red LED

Signal is not present or cannot be locked.

Biphase Coding
Error

Red LED

Biphase coding of incoming date is
incorrect.

Parity Error

Red LED

SRD stream’s parity bit is not set as
specified.

CRC Error

Red LED

The CRC value calculated for the
incoming data does not match the CRC
byte of the channel status word.

Confidence Flag
Error

Red LED

The received data eye opening is less
than a half-bit period, indicating a
possible lack of signal strength or high
jitter.

May also indicate that insufficient EA is
applied.

Validity Error

Red LED

AES stream’s validity bit is high.

The incoming data is not suitable for
conversion to an analog audio signal.

Alarm

Red LED

Indication that the external alarm
contact closure is asserted, and this card
is reporting an alarm.