Command protocol – Network Technologies RACKMUX-V17-8UNV User Manual

Page 22

Advertising
background image

NTI RACKMUX KVM Drawer with NODEMUX Switch

18






















Figure 17- Matrix-Y-1 wiring schematic

Unit Address

In order for a terminal to communicate with one or more NODEMUX switches, each switch must have a unique address. The
NODEMUX will only respond to commands from a terminal if its address is embedded in the command. Up to 15 NODEMUX
switches can be connected in a "daisy chain" to a terminal, each with its own unique address.

To set the address of the NODEMUX, from the Switch Configuration mode menu (Fig. 15 on page 17),
press <Tab> until the cursor bar moves to highlight "RS232 UNIT ADDRESS".
press <Up Arrow> or <Down Arrow> until the desired address (1-15) is selected.

Exit Switch Configuration Mode

Once changes are made to the Switch Configuration menu, press <Enter> and <Y> to save them.

To exit without saving, press <Esc>, then <N>, then <Esc> again. The menu will return to the Administration Mode without
saving the changes made. .

Changes made will take effect the next time the NODEMUX is power cycled.

Command Protocol

Terminal control commands supported by the NODEMUX are defined below.

Notes:

All commands should be terminated with an <Enter> (ASCII 13) denoted by <CR>. When a

command is sent, the entire string is echoed back to the terminal along with a response from the

addressed unit as shown in the command definitions. Unit response will be sent within 500 msec

after <CR>.

All characters should be upper case, and all numbers below 10 should have a leading 0 (ex: 1 = 01).

For units with one USER port (i.e. this NODEMUX switch), use 01 for the USER select.









(Unit #1)

(Source)

2

3

3

3

5

5

5

2

2

7
8

1
4
6

Jumper

Jumpers

Not connected to
source connector

(Unit #2)

9D Female

9D Male

9D Male

Wiring Schematic of Matrix-Y-1 cable