NTI RACKMUX KVM Drawer with NODEMUX Switch

19


RS - reset unit(s) to default power-up switch connections
FORMAT:

RS AA<CR>

RS = "reset unit" command followed by at least one space

AA = unit address; if 00, all units on the bus will be reset and no response will be

returned
RESPONSE:

*<CR> if command received and executed OK

-OR-

?<CR> if syntax or transmission error occurred

Note: The RS command does not change the switch configuration, it changes CPU-to-user connection settings.

CS - change single USER channel

FORMAT:

CS AA,XX,YY<CR>

CS = "change single output" command followed by at least one space

AA = unit address

XX = input/CPU to connect

YY = output/USER to change

RESPONSE:

*<CR> (command received and executed OK)

-OR-

?<CR> (syntax or transmission error occurred)



CA - change all output channels


FORMAT:

CA AA,XX<CR>

CA = "change all outputs" command followed by at least one space

AA = unit address

XX = input /CPU to connect to all outputs/USERS

RESPONSE:

*<CR> (command received and executed OK)

?<CR> (syntax or transmission error occurred)

FYI: In this NODEMUX switch, this command will have the same effect as the CS command above.

RO - read single USER channel

FORMAT:

RO AA,YY<CR>

RO = "read output" command followed by at least one space

AA = unit address

YY = output/USER to read

RESPONSE:

*<CR> (command received and executed OK)

XX<CR> (XX = input/CPU connected)

-OR-

?<CR> (syntax or transmission error occurred)

RU - read unit size

FORMAT:

RU AA<CR>

RU = "read unit size" command followed by at least one space

AA = unit address

RESPONSE:

*<CR> (command received and executed OK)

XX,YY<CR> (XX = # of CPU’s, YY = # of USERS)

-OR-

?<CR> (syntax or transmission error occurred)