1. To open

a) Loosen the two snap lockings by pulling them outwards
b) Lift the cover from the container.

2. Dust bag

Fit the opening on the dust bag over the air inlet. Press the

membrane over the flanged edge on the inlet. Secure with

the lock washer. Use only original dust bags.

3. Hose connection

Push the hose coupling all the way in and turn clockwise.

4. Wand assembly

Standard: Fit the sections together and twist to lock in

place.
Telescopic: Push down the catch and then adjust the length.

Max.950mm,min.630mm.

5. Tools

The accessories shown in the pictures may vary from model

to model.
a-b)Combination nozzle
Adjust the nozzle according to the requirements of the floor

you are cleaning. Work with the brush on hard floors and

without it on soft floors.
c) Universal nozzle
for both hard floors and carpets.
d)Crevice nozzle

Use to clean furniture, radiators and others hard-to-reach

places.
e)Small combi-nozzle:

The small combi-nozzle combines a dusting brush for furni-

ture, picture frames, mouldings etc. with a fold-out nozzle for

cleaning curtains, furniture and other soft surfaces. The clip

on the hose handle holds the nozzle when it is not in use.

6. Suction control

The suction control in the hose handle lets you regulate the

air-flow to prevent the nozzles from fastening to the surfaces

you are vacuum cleaning.

7. Start/Stop

a) Foot-operated on/off switch.
b)On the S2 version a separate switch is provided to

change the motor speed .
c)Plug-in point for powered carpet nozzle.
Power is supplied to the socket when the machine is

switched on.

8. Warning!

Never attempt to vacuum liquid, glass fragments or

ashes!
Wet surfaces can expose the operator to possible
electrical shock.

9. Filter

The filters are located inside the lid. To reach them lift out

the filter holder

(a). The standard filter(b) and fine filter (c)

should be inspected at regular intervals,e.g. when you

change dust bags, and replace if necessary.Instead of

these two filters you can fit a micro filter of HEPA-quality

(e),

wich traps 99,99% of all particles larger than 0,3 microns.

The machine is also fitted with a backup filter

(d) located

above the motor. This filter should also be inspected and

replaced if necessary.

IMPORTANT!

The GD 930/S2 is equipped with a specially

designed cable, which if damaged, must be replaced by

a cable of the same type. These cables are avaible at

authorized service shops and must be installed by trained

personnel.

The GD 930/S2 is equipped with a thermal cut-out to protect

the motor and other vital machine parts from overheating.

Should the machine cut out, you will have to wait at least

5-10 minutes for it to automatically reset. While you are

waiting, switch the machine off and unplug it, then check

the hose, dust bag and filters to be sure that nothing is

blocking the flow of air through the machine.

NB!

Remove the plug from the socket before performing service

or maintenance.

The symbol on the product or on its packing indicates that this

product may not be treated as household waste. Instead it shall be

handed over to the applicable collection point for the recycling of elec-

trical and electronic equipment. By ensuring this product is disposed

of correctly, you will help prevent potential negative consequences for

the environment and human health, which could otherwise be caused

by inappropriate waste handling of this product.

For more detailed information about recycling of this product, please

contact your local city office, your household waste disposal service or

the shop where you purchased the product.