Shock and vibration, Environmental – National Instruments RS485 User Manual

Page 19

Advertising
background image

© National Instruments Corp.

19

NI 9871 Operating Instructions

Shock and Vibration

To meet these specifications, you must panel mount the
CompactRIO system.

Operating vibration,
random (IEC 60068-2-64) ................ 5 g

rms

, 10 to 500 Hz

Operating shock
(IEC 60068-2-27).............................. 30 g, 11 ms half sine,

50 g, 3 ms half sine,
18 shocks at 6 orientations

Operating vibration,
sinusoidal (IEC 60068-2-6) .............. 5 g, 10 to 500 Hz

Environmental

CompactRIO modules are intended for indoor use only. For
outdoor use, mount the CompactRIO system in a suitably rated
enclosure. Refer to the installation instructions for the chassis you
are using for more information about meeting these specifications.

Operating temperature ...................... –40 to 70 °C

Storage temperature .......................... –40 to 85 °C

Ingress protection.............................. IP 40