NI 9871 Operating Instructions

4

ni.com

Caution

For Zone 2 applications, install a protection

device between the RS485/RS422 signal cables and the
NI 9871 RJ-50 jacks (ports 1– 4). The device must
prevent the RS485/RS422 signal-to-signal or
signal-to-COM voltage from exceeding 23 V if there is a
transient overvoltage condition.

Caution

For Zone 2 applications, install a protection

device between the external power supply and the
NI 9871 V

sup

and COM pins. The device must prevent the

V

sup

-to-COM voltage from exceeding 39 V if there is a

transient overvoltage condition.

Special Conditions for Hazardous Locations in Europe

This equipment has been evaluated as Ex nA IIC T4 equipment
under DEMKO Certificate No. 07 ATEX 0626664X. Each module
is marked

II 3G and is suitable for use in Zone 2 hazardous

locations. If you are using the NI 9871 in Gas Group IIC hazardous
locations or in ambient temperatures of –40

°C ≤

Ta

70

°C, you

must use the device in an NI chassis or controller that has been
evaluated as EEx nC IIC T4, Ex nA IIC T4, or Ex nL IIC T4
equipment.