B-15 – Nvidia MS-7374 User Manual

Page 101

Advertising
background image

B-15

nVidia RAID

RAID 0

m >= n2
Number of RAID 0 disks must be equal to or greater than half the number
of RAID 0+1 disks.

RAID 1

** Not a valid combination **

RAID 0+1

** Not a valid combination **

RAID 0+1

RAID 5

m >= (n/2 + 1)

RAID 0

m >= n - 1

RAID 1

** Not a valid combination **

RAID 0+1

m >= 2 x (n -1) ; where m is an even number of disks.

RAID 5

RAID 5

m >= n

Specific M igrating Requirements
The following table lists the disk requirements for a new RAID array for various
migrating combinations.

From

To

New Array Disk Requirements

RAID 0

m > n
Number of disks in the new array must be greater than the original array.

RAID 1

m =2, n =1
RAID 1 array must include two disks, converted from a one disk RAID 0
array.

RAID 0+1

m >= 2 x n
Number of RAID 0+1 disks must be equal to or greater than twice the
number of RAID 0 disks.

RAID 0

RAID5

m >= n+1

RAID 0

No additional restrictions.

RAID 1

** Not a valid combination **

RAID 0+1

No additional restrictions.

RAID 1

RAID 5

m >= 3

Instr uctions
Click Migrate array to start the Migrate Array W izard and then follow instructions.
You can press F1 to access the online help that walks you through the W izard with
step-by-step instructions.