6.4.4 Operation in 16-bit timer counter mode

In this mode, two timer counter channels, 1 and 2, are used in combination to implement 16-bit programmable

interval timer or event timer operation.

(1) Register setting

In the 16-bit timer counter mode, the following seven registers are used.

•

Timer counter mode registers TM1 and TM2

•

Timer counter control register TC2

Note

•

Timer count registers T1 and T2

•

Timer count modulo registers TMOD1 and TMO2

Note Timer counter channel 1 uses the timer counter output enable flag (TOE1).

(a) Timer counter mode registers (TM1 and TM2)

In the 16-bit timer counter mode, TM1 and TM2 are set as shown in Figure 6-40 (for the formats of TM1

and TM2, refer to Figure 6-27 Format of Timer Counter Mode Register (Channel 1) and Figure 6-

28 Format of Timer Counter Mode Register (Channel 2)).

TM1 and TM2 are manipulated by an 8-bit manipulation instruction. Bit 3 of these registers is a timer start

command bit that can be manipulated in 1-bit units and is automatically cleared to 0 when the timer starts

operating.

TM1 and TM2 are cleared to 00H when the internal reset signal is asserted.

The flags shown by a solid line in Figure 6-39 are used in the 16-bit timer counter mode.

Do not use the flags shown by a dotted line in the 16-bit timer counter mode (clear these flags to 0).