5 operation in carrier generator mode (cg mode) – NEC PD754144 User Manual

Page 160

Advertising
background image

CHAPTER 6 PERIPHERAL HARDWARE FUNCTION

160

User’s Manual U10676EJ3V0UM

6.4.5 Operation in carrier generator mode (CG mode)

In the PWM mode, timer counter channels 1 and 2 operate in combination to implement an 8-bit carrier generator

operation.

When using CG mode, use it in combination with channel 1 and channel 2 of the timer counter.

Timer counter channel 1 generates a remote controller signal.

Timer counter channel 2 generates a carrier clock.

(1) Register setting

In the CG mode, the following eight registers are used.

•

Timer counter mode registers TM1 and TM2

•

Timer counter control register TC2

Note

•

Timer counter count registers T1 and T2

•

Timer counter modulo registers TMOD1 and TMOD2

•

Timer counter high-level period setting modulo register TMOD2H

Note Timer counter channel 1 uses the timer counter output enable flag (TOE1).

(a) Timer counter mode registers (TM1 and TM2)

In the CG mode, set TM1 and TM2 as shown in Figure 6-44 (for the formats of TM1 and TM2, refer

to Figure 6-27 Format of Timer Counter Mode Register (Channel 1) and Figure 6-28 Format of

Timer Counter Mode Register (Channel 2)).

TM1 and TM2 are manipulated by an 8-bit manipulation instruction. Bit 3 of TM1 and TM2 is timer start

command bit which can be manipulated in 1-bit units and is automatically cleared to 0 when the timer

starts operating.

TM1 and TM2 are also cleared to 00H when the internal reset signal is asserted.