Table c-1. common clk10 routing configurations – National Instruments VXI-1394 User Manual

Page 48

Advertising
background image

Appendix C

Advanced Hardware Configuration Settings

© National Instruments Corporation

C-7

VXI-1394 User Manual for Windows

Table C-1 summarizes the most common configuration types.

Figure C-4 shows the default settings for the CLK10 switches. This
configuration is as follows:

CLK10 is generated from the onboard oscillator (S5).

The CLK10 signal is not terminated (S1).

The VXI-1394 receives the external CLK10 signal (S2).

The polarity of the CLK10 signal (S3) is irrelevant when the VXI-1394
receives the external CLK10 signal. However, it is configured to be
inverted when the CLK10 SMB is used as output.

Table C-1. Common CLK10 Routing Configurations

Description

Switches

S1

Terminate

S2

Direction

S3

Polarity

S5 CLK10

Source

Generate internal CLK10 with
onboard oscillator

N

IN

N/A

ONBRD

Generate internal CLK10 and drive
to external CLK SMB

N/A

OUT

NON

ONBRD

Generate internal CLK10 and drive
inverted to external CLK SMB

N/A

OUT

INV

ONBRD

Receive external CLK SMB and
drive to the backplane unterminated

N

IN

N/A

SMB

Receive external CLK SMB with
50

Ω termination and drive to the

backplane

Y

IN

N/A

SMB

Advertising