Shock and vibration – National Instruments NI 9476 User Manual

Page 19

Advertising
background image

© National Instruments Corp.

19

NI 9476 Operating Instructions and Specifications

Operating humidity
(IEC 60068-2-56).............................. 10 to 90% RH,

noncondensing

Storage humidity
(IEC 60068-2-56).............................. 5 to 95% RH,

noncondensing

Maximum altitude............................. 2,000 m

Pollution Degree (IEC 60664) .......... 2

Shock and Vibration

To meet these specifications, you must panel mount the system.

Operating vibration

Random (IEC 60068-2-64)......... 5 g

rms

, 10 to 500 Hz

Sinusoidal (IEC 60068-2-6) ....... 5 g, 10 to 500 Hz

Operating shock
(IEC 60068-2-27).............................. 30 g, 11 ms half sine,

50 g, 3 ms half sine,
18 shocks at 6 orientations

Advertising