5 Technical Specifications

5.1 Operating Environment

Parameter

Range

Comments

Ambient Operating Temperature

-40 to 85

°C

Ambient Temperature as

measured from a 30 cm radius

surrounding the center of the

RS910 enclosure.

Ambient Storage Temperature

-40 to 85

°C

Ambient Relative Humidity

5% to 95%

Non-condensing

Table 6 - Operating Environment

5.2 Power Supply Specifications

Power Supply Type

Minimum

Input

Maximum

Input

Fuse

Rating

Isolation

Maximum Power

Consumption

12 – 24 VDC

10 VDC

36 VDC

3.15 (T)

1.5 kV DC

24 VDC

18 VDC

36 VDC

3.15 (T)

1.5 kV DC

48 VDC

36 VDC

72 VDC

3.15 (T)

1.5 kV DC

HI (125/250 VDC) 1
HI (110/230 VAC) 1

88 VDC
85 VAC

300 VDC
265 VAC

3.15 (T)

4 kV AC 5.5

kV DC

10W

Table 7 - Power Supply Specifications

NOTES:

1.

This is the same power supply for both AC and DC.

2.

(F) Denotes fast-acting fuse, (T) denotes time-delay fuse.

3.

For continued protection against risk of fire, replace only with same type and rating of fuse.

5.3 Failsafe Relay Specifications


Load Circuit

SELV

TNV-2

MAX operating Voltage

30VDC

30 VAC

80VDC

MAX operating Current

1A

0.5A

0.3A

Isolation (between coil and contacts)

1800 V

rms

Table 8 - Failsafe Relay Specifications