3 iec environmental type tests – RuggedCom RUGGED VDSL RS910L User Manual

Page 28

Advertising
background image

28

2007 RuggedCom Inc. All rights reserved

Rev100

6.2 IEEE 1613 Type Tests

Test

Description

Test Levels

Enclosure Contact

+/- 8kV

IEEE C37.90.3

ESD

Enclosure Air

+/- 15kV

IEEE C37.90.2

Radiated RFI

Enclosure ports

35 V/m

Signal ports

+/- 4kV @ 2.5kHz

D.C. Power ports

+/- 4kV

A.C. Power ports

+/- 4kV

IEEE C37.90.1

Fast Transient

Earth ground ports

+/- 4kV

Signal ports

2.5kV common mode @ 1MHz

D.C. Power ports

2.5kV common & differential mode @ 1MHz

IEEE C37.90.1

Oscillatory

A.C. Power ports

2.5kV common & differential mode @ 1MHz

Signal ports

5 kV (Failsafe Relay)

D.C. Power ports

5 kV

IEEE C37.90

H.V. Impulse

A.C. Power ports

5 kV

Signal ports

2kVac (Failsafe Relay)

D.C. Power ports

2kVac

IEEE C37.90

Dielectric

Strength

A.C. Power ports

2kVac

Table 17 - IEEE 1613 Type Tests


NOTE:

If the unit contains copper ports the IEEE 1613 conformance is Class 1 (During disturbance errors may occur
but recovery is automatic).

If the unit contains all fiber ports the IEEE 1613 conformance is Class 2 (During disturbance no errors will
occur).


6.3 IEC Environmental Type Tests

Test

Description

Test Levels

Severity

Levels

IEC 60068-2-1

Cold Temperature

Test Ad

-40 deg. C, 16 Hours

N/A

IEC 60068-2-2

Dry Heat

Test Bd

+85 deg. C, 16 Hours

N/A

IEC 60068-2-30

Humidity (Damp Heat,

Cyclic)

Test Db

95% (non-condensing), 55 deg C, 6 cycles

N/A

IEC 60255-21-1

Vibration

Tests Fc

2g @ (10-150) Hz

Class 2

IEC 60255-21-2

Shock

Tests Ea

30g @ 11ms

Class 2

Table 18 - Environmental Type Tests

Advertising