RuggedCom RUGGED VDSL RS910L User Manual

Page 9

Advertising
background image

9

2007 RuggedCom Inc. All rights reserved

Rev100

2.2 Power Supply Wiring and Grounding

2.2.1 AC Power Supply Wiring and Grounding

Figure 4 - RS910L Power Supply Inputs


The RS910L AC power supply inputs should be connected as follows:

1.

+/L should be connected to AC Line/Hot.

2.

-/N should be connected to AC Neutral.

3.

Surge Ground should be connected to the Chassis Ground via a braided cable or other

appropriate grounding wire. Surge Ground is used as the ground conductor for all surge
and transient suppression circuitry internal to the unit.

4.

Chassis Ground must be connected to the AC ground terminal.

NOTES:

1.

Equipment must be installed according to the applicable country wiring codes.

2.

All line-to-ground transient energy is shunted to the Surge Ground terminal. In cases

where users require the inputs to be isolated from ground, remove the ground braid
between Surge and Chassis Ground. Note that all line-to-ground transient protection
circuitry will be disabled.

Advertising