Chapter 1– setting up and administering the switch, Introduction, The ruggedswitch user interface – RuggedCom RS1600 User Manual

Page 15: Using the rs232 port to access the user interface, The ruggedswitch™ user interface

Advertising
background image

Chapter 1– Setting Up And Administering The Switch

Chapter 1– Setting Up And Administering The Switch

Introduction

This chapter familiarizes the user with the RuggedCom user interface as well as
describes the following procedures:

• Configuring the IP Address and Subnet Mask
• Configuring the Gateway Address
• Configuring for DHCP Operation
• Configuring the Management Connection Inactivity Timeout
• Configuring the number of Telnet Sessions
• Configuring TFTP Server Permissions

• Configuring the SNMP Get Community Name
• Configuring the System Identification
• Configuring Passwords
• Configuring the time and date
• Configuring SNTP to keep the time and date correct
• Configuring SNMP Management Stations

The RuggedSwitch™ User Interface

Using the RS232 Port to Access the User Interface

Attach a terminal (or PC running terminal emulation software) to the RS232 port
on the rear of the chassis. The terminal should be configured for 8 bits, no parity
operation at 57.6 Kbps. Hardware and software flow control must be disabled.
Select a terminal type of VT100.

Once the terminal is connected, pressing <CR> will prompt for the password to
be entered. The switch is shipped with a default administrator password of
admin”. Once successfully logged in, the user will be presented with the main
menu.

RuggedCom

RuggedCom

Advertising