Shutdown Time

This is the length of time to shut the port down when an unauthorized frame is
received in port security mode.

If this option is set to “Don’t Shutdown”, the frame will simply be filtered.

If this option is set to “Until Reset”, the port will be shutdown until a port reset
command is issued or the switch is reset.

This option can also take the number of seconds (1 to 86384) to hold the port
down.

Note:

The port is also reset whenever a parameter in the Port Configuration and Status menu

is changed.

Status

This parameter’s message describes the port security status including disabled
ports and ports that have been shut down because of security violations. If
autolearning is configured, this parameter displays whether it is taking place. The
number of entries in the Static MAC Address table for this port is also provided.

Port Mirroring Menu

The Configure Port Mirroring command enables port mirroring.

Figure 16: Port Mirroring Menu

My Switch Port Mirroring Admin Access

Port Mirroring Disabled
Source Port 1
Target Port 1

<CTRL>

Z-Help S-Shell

Port Mirroring

Enable or disable port mirroring with this command.

Note:

Port mirroring will be disabled upon the next reset of the switch.

Source Port

Select the source port with this command.

Target Port

Select the target port with this command.