Maintenance and Troubleshooting

58

Vistage™ Series Flat-Panel Display Installation/Operation Manual

PRE

L

IMINAR

Y

The display is jittery or
unstable.

• Poor-quality or improperly

connected source.

• The horizontal or vertical

scan frequency of the
input signal may be out of
range for the display.

• Ensure that the source is

properly connected and of
adequate quality for
detection.

• Correct at the source.

Image is too bright and/or
lacks definition in the bright
areas of the image.

• Contrast is set too high.

• Lower the contrast setting.

Image appears “washed out”
and/or dark areas appear too
bright.

• Brightness is set too high.

• Lower the brightness

setting.

Colors in the image are
swapped; for example, reds
appear blue or vice versa.

• The Red/Pr, Green/Y or

Blue/Pb outputs from the
source are connected to
the wrong inputs on the
DHD Controller.

• Ensure that the source

outputs are connected to
the correct DHD Controller
input.

Table 5-1. Troubleshooting Chart (continued)

Symptom

Possible Cause(s)

Solution