Maintenance instructions, Glass gasket, General vent maintenance – Regency L900E-NG User Manual

Page 36: Log replacement, Door glass, Glass replacement, Maintenance

Advertising
background image

Regency

®

L900E Direct Vent Gas Fireplace

36

MAINTENANCE

MAINTENANCE

MAINTENANCE

INSTRUCTIONS

1) Always turn off the unit before cleaning. For

relighting, refer to lighting instructions. Keep
the burner and control compartment clean
by brushing and vacuuming at least once
a year. When cleaning the logs, use a soft
clean paint brush as the logs are fragile and
easily damaged.

2) Clean appliance and door with a damp

cloth (never when unit is hot). Never use
an abrasive cleaner. The glass should be
cleaned with a gas fi replace glass cleaner.
The glass should be cleaned when it
starts looking cloudy.

3) The heater is fi nished in a heat resistant

paint and should only be refi nished with heat
resistant paint. Regency

®

uses StoveBright

Paint - Metallic Black #6309.

4) Make a periodic check of burner for proper

position and condition. Visually check the
fl ame of the burner periodically, making sure
the fl ames are steady; not lifting or fl oating.
If there is a problem, call a qualifi ed service
person.

5) The appliance and venting system must be

inspected before use, and at least annually,
by a qualifi ed fi eld service person, to ensure
that the fl ow of combustion and ventilation
air is not obstructed.

Note: Never operate the appliance without

the glass properly secured in place.

6) Do not use this appliance if any part has been

under water. Immediately call a qualifi ed
service technician to inspect the appliance
and to replace any part of the control system
and any gas control which has been under
water.

7) In the event this appliance has been

serviced check that the vent-air system
has been properly resealed & reinstalled
in accordance with the manufacturer's
instructions.

8) Verify operation after servicing.

GLASS GASKET


If the glass gasket requires replacement use a
tadpole glass gasket (Part # 936-155).

GENERAL VENT

MAINTENANCE

Conduct an inspection of the venting system
semiannually. Recommended areas to inspect
as follows:

1) Check the Venting System for corrosion in

areas that are exposed to the elements.
These will appear as rust spots or
streaks, and in extreme cases, holes.
These components should be replaced
immediately.

2) Remove the Cap, and shine a fl ashlight

down the Vent. Remove any bird nests, or
other foreign material.

3) Check for evidences of excessive

condensation, such as water droplets forming
in the inner liner, and subsequently dripping
out the joints, Continuous condensation can
cause corrosion of caps, pipe, and fi ttings.
It may be caused by having excessive
lateral runs, too many elbows, and exterior
portions of the system being exposed to
cold weather.

4) Inspect joints, to verify that no pipe

sections or fi ttings have been disturbed,
and consequently loosened. Also check
mechanical supports such as Wall Straps,
or plumbers' tape for rigidity.

LOG REPLACEMENT

The unit should never be used with broken logs.
Turn off the unit and allow the unit to cool before
opening door and carefully remove the logs. If
for any reason a log should need replacement,
you must use the proper replacement log. The
position of these logs must be as shown in the
diagrams under Log Installation.

Note: Improper positioning of logs may

create carbon build-up and will
severely alter the unit's performance
w h i c h i s n o t c o v e r e d u n d e r
warranty.

CAUTION: Wear gloves when
removing damaged or broken
glass.

WARNING: Do not operate the
appliance with the glass panels
removed, cracked or broken.
Replacement of the glass panels
should be done by a licensed or
qualifi ed service person.

DOOR GLASS

Your Regency

®

fi replace is supplied with high

temperature 5mm-Ceramic glass. If your glass
requires cleaning, we recommend using an
approved glass cleaner available at all authorized
dealers. Do not use abrasive materials.

CAUTION & WARNINGS:

* Do not clean when the glass is hot.
* The use of substitute glass will void all product

warranties.

* Care must be taken to avoid breakage of the

glass.

* Do not strike or abuse the glass.
* Do not operate this fi replace without the

glass front or with a cracked or broken glass
front.

* Wear gloves when removing damaged or

broken glass.

* Replacement of the glass panel(s) should be

done by a licensed or qualifi ed service per
son.

GLASS REPLACEMENT

In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency

®

dealer only.

Replacement glass is shipped already installed
into the door frame.

Advertising