1.8

Absolute Maximum Ratings

Rev.1.04 2008.07.10

1-11

REJ10J1564-0104

1

1.8 Absolute Maximum Ratings

Table 1.8.1 lists the absolute maximum rating of M3A-HS85.

Table 1.8.1 Absolute Maximum Ratings of M3A-HS85

Symbol Parameter Rated

Value

Remarks

5VCC

5V System Power Supply Voltage

-0.3V to 6.0V

Relative to VSS

3VCC 3.3V System Power Supply

Voltage

-0.3V to 4.6V

Relative to VSS

Topr

Operating Ambient Temperature

0°C to 50°C

No dewdrops allowed.

Use in corrosive gas environment prohibited.

Tstr

Storage Ambient Temperature -10°C to 60°C

No dewdrops allowed.

Use in corrosive gas environment prohibited.

Note: The ambient temperature refers to the air temperature in places closest possible to the board.

1.9 Recommended Operating Conditions

Table 1.9.1 lists the recommended operating conditions of M3A-HS85.

Table 1.9.1 Recommended Operating Conditions of M3A-HS85

Symbol Parameter Rated

Value

Remarks

5VCC

5V System Power Supply Voltage

4.5V to 5.5V

Relative to VSS

3VCC 3V System Power Supply Voltage

3.0V to 3.6V

Relative to VSS

-

Maximum Current Consumption in

the Board

Within 1A

Topr

Operating Ambient Temperature

0°C to 50°C

No dewdrops allowed.

Use in corrosive gas environment prohibited.