Operational specifications – Renesas M3A-HS85 User Manual

Page 52

Advertising
background image

Operational Specifications

3.2.2 External Power Supply Select Jumper (JP2, JP3, JP4, JP5)

Rev.1.04 2008.7.10

3-20

REJ10J1564-0104

3

3.2.2 External Power Supply Select Jumper (JP2, JP3, JP4, JP5)

By setting JP2 to JP5, the source of power voltage supplying to A/D reference power supply (AVREF), analog

power supply (AVCC), USB power supply (DrVCC), and system power supply of SH7285 can be switched.

Figure 3.2.3 shows the external power supply select jumper assignments. Table 3.2.2 lists the external power

supply select jumper setting.

Top view of the

component side

1

2

CPU-VCC SEL

FIX INT

JP2

1

2

DrVCC SEL

FIX INT

JP3

1

2

AVCC SEL

F

IX AVC

C

JP4

1

2

AVREF SEL

FI

X

A

V

R

E

F

JP5

Figure 3.2.3 External Power Supply Select Jumper Assignments (JP2,JP3,JP4,JP5)

Table 3.2.2 External Power Supply Select Jumper Setting (JP2,JP3,JP4,JP5)

Jumper Setting

Function

1-2

SH7285 power supply voltage (VCC) is supplied from J4 or J7

JP2

CPU-VCC SEL

Open

External power supply voltage (supplied from J5 or H13)

1-2

SH7285 USB power supply (DrVCC) is supplied from J4 or J7 (via regulator)

JP3

DrVCC SEL

Open

External power supply voltage (supplied from J6 or H14)

1-2

SH7285 AVCC is connected to 5V fixed power supply voltage.

JP4

AVCCSEL

Open

External power supply voltage (supplied from J8 or H8)

1-2

SH7285 AVREF is connected to 5V fixed power supply voltage.

JP5

AVREFSEL

Open

External power supply voltage (supplied from J8 or H9)

: Initial Setting

Note: Do not change jumper settings during the operation of M3A-HS85.

Ensure to turn off the power for the M3A-HS85 before changing jumper settings.

Advertising