– 16 –

VENT LOCATION

FITTING TOP SPACER + WALL CLIP

FLUE MANIFOLD POSITION

Center of hole for flue manifold can be drilled
anywhere within the shaded area. (To avoid studs,
etc.)

FOR WEATHERBOARD WALLS DRILL THROUGH
CENTER OF WEATHER BOARD FROM OUTSIDE,
THEN DRILL FROM INSIDE THROUGH PLASTER-
BOARD.

Before drilling the flue hole, check for water and gas
pipes as well as electric cables. Use a 3 1/8"
(80mm) drill for hole through wall.

WALL MOUNTING BRACKETS

Place top back spacer in position. Mark the position
of the top edge of the top space on the wall. Move
the heater away from the wall. Mark center lines 1
1/8" (30mm) down from the top edge mark, and 1
9/16" (40mm) in front the left and right hand sides of
the top spacer. Attach wall brackets at the marked
position.

Tighten all screws.

Replace top spacer, clipping the spacer into the wall
brackets at the same time as attaching it to the
heater. Secure top spacer with the screws provided.
THE HEATER IS NOW SECURED TO THE WALL.

Replace fan filter.

SECURE HEATER TO WALL

Flue Hole

3 1/8"

(80mm)

8 7/16"

(214mm)

R11"

(R279mm)

R8.0"

(R206mm)

8 9/16"

(217mm)

11"

(280mm)

Cavity Opening

Spacer bracket

Top spacer

Top spacer

Wall bracket

Spacer bracket

Spacer