1. How to connect exhaust pipes

2. How to connect air intake hose

To connect the exhaust pipes, fit the male end into the female end and clamp with pipe stopper A to prevent
slipping. The exhaust pipe can be telescoped to the required length; do not cut it.

Screw hose joint half of its length onto the air intake hose, then screw another air intake hose into the joint.
The hose can be cut to the required length.
IMPORTANT: The PVC air line is longer than the exhaust line and may need to be cut to size. Be sure,
however, to thoroughly deburr all rough edges.

Set the air intake hose and exhaust pipe into the pipe
clamps, screw the clamp onto the wall fixture, and affix
to the wall with screw B.
The air intake hose and exhaust pipe can also be
screwed onto the wall using the pipe clamp and
the nut.

With the exhaust pipes inserted into the ends, bend
the bent pipe to the angle reguired for installation.
This part is mainly used for curves and for connection
to vent terminal.

3. Affixing the air intake hose and exhaust pipe

4. How to use the bent pipe

Female end

Exhaust pipe

Pipe stopper B

Male end

Pipe stopper B

Pipe stopper A

Female end

Male end

Exhaust pipe

Fit inside

Pipe stopper A

Fit inside

Connect bent pipe

Female end

Male end

Main unit air intake hose

Air intake hose

Hose joint

Screw in counterclockwise

Air intake hose

Air intake elbow

Screw B

Wall

Air intake
hose

Screw A

Pipe clamp

Exhaust pipe

Wall fixture

Wall

Air intake
hose

Screw A

Nut

Pipe clamp

Exhaust pipe

Adjust the angle

NOTE: Maintain 1" clearance between exhaust pipe
and combustible materials (0" clearance between
exhaust pipe and non-combustible materials).

Advertising