CAUTIONS

1. Maximum extendable length

FOR BEST ROOM AIR HUMIDITY, KEEP WATER
IN THE HUMIDIFIER TRAY.

13 feet, 2 bends
The bend where the hose and pipes leave the body is
not counted.
The air intake hose should run along the exhaust pipe.

2. To prevent water condensation

CAUTION

Never allow the exhaust pipe to sag, as condensed
water may accumulate and cause incomplete
combustion.

3. Condensed water formed by

combustion, will run back to the
unit, and may overflow from the
condensation pan if pipes are
longer then 8 feet. Therefore, pipes
exceeding these lengths should be
made to drain to the outside by
giving their horizontal portions 3˚ or
more downward and outward slope.

Condensed water
may accumulate
here, and cause a blockage
preventing combustion.

3˚ slope(approximate)

Less than 8 ft.