background image

– 36 –

SW6, DIP SWITCH

SW1 FM, ADJUST SWITCH

Hi

SW2 FM, ADJUST SWITCH

Lo

SW3 POV, PRESSURE ADJUST SWITCH

Hi

SW5, TEST SWITCH

SW4 POV, PRESSURE ADJUST SWITCH

Lo

TH

TB

AC

ER

SP

120V

OH.TH

MS

CONTROL DISPLAY UNIT

H

2

H

1

H

3

OHS

FR

TR

130

TF

TF

OHS

OHS

No 3

130

No 1

130

No 2

90

152

44

45

43

46

39

40

31

32

33

24

25

27

28

23

29

30

21

22

19

15

F

3A

16

17

18

20

12

13

9

1 2 3 4

12

3

8

OFF

26

38

37

34

35

36

41

42

I

A

D

B

C

H

F

G

E

E

1

SV

1

SV

2

POV

BL

FM

r

r

r

r

r

r

r

bl

bl

bl

bl

bl

Y

Y

bk

W

Y

Y

Y

Y

Y

Y

W

W

W

W

r

W

bk

bk

bk

bk

bk

bk

bk

or

or

gr/y

W

WW

W

Wr

r

47 48 49 50 51 52 53 54 55 56

57 58 59 60 61 62 63 64 65

66 67 68

bl

bl

bl

bl
bl

bl

bl

bl

bl

W

W

W1

W

gr/y

gy

gy

gy

gr

gy

gy

gy

gy

gy

5 6 7

4

K

If any of the original wire as supplied with the appliance must be

replaced, it must be replaced with a wire of a least a 194

°F

temperature rating and number 18AWG or its equivalent.

“CAUTION: Label all wires prior to disconnection when servicing

controls. Wiring errors can cause improper and dangerous operation.

Verify operation after servicing

CODE

COLOR

black

blue

brown

green

green/yellow

purple

bk

bl

br

gr

gr/y

pl

red

r

white

w

yellow

y

grey

gy

orange

or

MARK

MS

TH

TF

F

ER

POV

TR

FR

OH. TH

OHS1

3

FM

SP

SV1

2

BL

TB

PART NAME

MAIN SWITCH

THERMISTOR

THERMAL FUSE

FUSE

ELECTRODE

MODULATING SOLENOID VALVE

TRANSFORMER

FLAME ROD

OVER HEAT THERMISTOR

OVER HEAT SWITCH

CONVECTION FAN MOTOR

SPARKER

MAIN SOLENOID VALVE 1

2

COMBUSTION FAN MOTOR

TERMINAL BLOCK