Specifications, Troubleshooting, Power indicator is not lit – ROTEL RA-1062 User Manual

Page 9: Fuse replacement, No sound, English

Advertising
background image

9

Specifications

Continuous Power Output

60 watts/channel (20-20 kHz, < 0.03%, 8 ohms)

Total Harmonic Distortion (20Hz-20kHz)

< 0.03% at rated power, 1/2 power, or 1 watt

Intermodulation Distortion (60 Hz : 7 kHz, 4:1) < 0.03% at rated power, 1/2 power or 1 watt
Frequency Response

Phono Input

20Hz-15kHz, ±0.2dB

Line Level Inputs

10Hz-100kHz, +1, –3dB

Damping Factor (20-20,000 Hz, 8 ohms)

150

Line Input Sensitivity / Impedance

160 mV / 24 kOhms

Line Input Overload

5 V

Phono (MM) Sensitivity / Impedance

2.4mV /47 kohms

Input (Phono) Overload

170 mV

Preamplifier Output / Impedance

1V / 470 ohms

Signal to Noise Ratio (IHF “A” weighted)

>95 dB

Power Requirements

USA:

115 Volts, 60 Hz

EC:

230 Volts, 50 Hz

Power Consumption

300 Watts

Dimensions (W x H x D)

430 x 92 x 355 mm

17 x 5

5

/

8

x 14 inches

Front Panel Height

80mm / 3

3

/

16

inches

Weight (net)

7.8 kg, 17.2 lbs.

All specifications are accurate at the time of printing.
Rotel reserves the right to make improvements without notice.
Rotel and the Rotel HiFi logo are registered trademarks of The Rotel Co, Ltd., Tokyo, Japan.

Troubleshooting

Most difficulties in audio systems are the result
of incorrect connections, or improper control
settings. If you encounter problems, isolate the
area of the difficulty, check the control settings,
determine the cause of the fault and make the
necessary changes. If you are unable to get
sound from the RA-1062 refer to the sugges-
tions for the following conditions:

Power Indicator Is Not Lit

The power indicator should be lit whenever the
RA-1062 is plugged into the wall power outlet
and the POWER switch is pushed in. If it does
not light, test the power outlet with another
electrical device, such as a lamp. Be sure the
power outlet being used is not controlled by
a switch that has been turned off.

Fuse Replacement

If another electrical device works when plugged
into the power outlet, but the power indicator
still will not light when the RA-1062 is plugged
into the wall outlet, it indicates that the internal
power fuse may have blown. If you believe this
has happened, contact your authorized Rotel
dealer to get the fuse replaced.

No Sound

Check the signal source to see if it is func-
tioning properly. Make sure the cables from
the signal source to the RA-1062 inputs are
connected properly. Be sure the LISTENING
selector is set to the proper input. Be sure the
SPEAKERS selector is set to the proper posi-
tion. Check the wiring between the RA-1062
and the speakers.

English

Advertising