34

Specifications

Relative Humidity

Operating Measurement ............................................................................................................ 25–90% RH

Accuracy:

Indoor Range: 40–80% ..................................................................................................................... ±5%

Outdoor Range: 25–90% .................................................................................................................. ±7%

Resolution (Indoor and Outdoor) ............................................................................................................. 1%

Sampling Cycle Frequency

Indoor ................................................................................................................................... 38 Seconds

Outdoor ................................................................................................................................. 37 Seconds

Dew Point Temperature

Temperature Operating Range:

Indoor .......................................................................................................... 14° to 140°F (–10° to 60°C)

Outdoor ........................................................................................................ 14° or 140°F (–10° to 60°C)

Measurement Accuracy (Indoor and Outdoor):

Conditions: 25–90% RH: 14° to 104°F (–10° to 40°C) ........................................................ ±18°F (±9°C)

Resolution (Indoor and Outdoor) ................................................................................................... 2°F (1°C)

Sampling Cycle Frequency:

Indoor ................................................................................................................................... 38 Seconds

Outdoor ................................................................................................................................. 37 Seconds

Wind Speed

Operating Measurement ........................................................................................ 0–125.3 mph (0–56 m/s)

Measurement Accuracy:

Range: 2 –10 m/s: 32° to 104°F (0° to 40°C) ............................................................................... ±1 m/s

Other temperature ranges ............................................................................................................ ±3 m/s

Resolution .................................................................................................................... 0.2 m/s (0.4 mph)

Sampling Cycle Frequency:

Gust Wind Mode ..................................................................................................................... 5 Seconds

Average Wind Mode .................................................................................................................. 1 Minute

Wind Direction

Operating Measurement .............................................................................................. 0° to 359° (Degrees)

0° to 350° (Compass Direction)

Measurement Accuracy:

Range: 0°–347° .................................................................................................................................. ±8°

Range: 347°–359° ............................................................................................................................ ±18°

Resolution ................................................................................................................................ 1° (Degrees)

10° (Compass Direction)

Wind Chill Temperature

Measurement Display Range ....................................................................... –146° to 158°F (–99° to 70°C)