Installation, Cb a – Regency IG34-LPG User Manual

Page 13

Advertising
background image

13

Regency IG34 Gas Inbuilt Fireplace

INSTALLATION

Installer Notice:
These instructions must be left
with the appliance.


After carrying out all adjustments, block the setting screws
with paint, taking care not to obstruct the breather orifi ce
of the pressure.

Put back the modulator plastic cap.

WARNING: To ensure the correct operation of the modu-
lator it is necessary that the plastic cap (A) is returned to
its original location.

C

B

A

18) Turn on gas supply and plug in

power cord.

19) Adjusting the Outlet Pressure

All the adjustments must be
carried out in the following order:

Remove the modulator plastic cap (A) using needle nose
pliers.

Maximum pressure: Turn the unit ON to its highest input
rating. Screw in the nut (B) to increase the outlet pressure
and screw it out to decrease it. Use a 10 mm wrench.

NOTE: The outlet pressure must be set to maximum 2.51
kPa.

Minimum pressure: Remove one of the cables connect-
ed to the electric modulator. While holding the nut (B) with
a wrench, screw in the screw (C) to increase the pressure
and screw it out to decrease it. Use a screwdriver 6 x 1
blade.


NOTE: The outlet pressure must be set to minimum 1.6

kPa.

Cable

Electric

Modulator

20) Turn on gas supply and plug in power cord.

21) At the end of all setting and adjustment operations, check

electrical installation and gas leaks.

22) Check operation of fl ame control.

23) Check for proper fl ame appearance and glow on logs.