Quantum 600 XL User Manual

Page 36

Advertising
background image

36

www.quantumrehab.com

Quantum 600 XL

V I I . O P E R A T I O N

Horn Key

The horn key activates the horn.

Speed Keys

There are two keys that control the speed. Press the hare key to increase the speed. Press the tortoise key to decrease the
speed. The speed setting is displayed on the speed indicator. If your power chair was programmed with a drive profile,
contact your Quantum Rehab Specialist for more information.

NOTE: We recommend that the first few times you operate your power chair, you set the speed to the slowest
setting until you become familiar with your new power chair.

Off-board Charger/Programming Socket

You may use an off-board charger to charge the power chair batteries through the 3-pin socket located on the front of the
FLIGHT. If you use an off-board charger, the charger current should not exceed 8 amps. Contact your Quantum Rehab
Specialist for more information.

WARNING! Only chargers with Neutrik NC3MX plugs should be connected to the off-board charger/

programming socket. See your Quantum Rehab Specialist for more information.

NOTE: The socket may also be used for reprogramming the FLIGHT. Contact your Quantum Rehab Special-
ist for more information.

Sleep Mode (If Enabled)

The power chair controller features a sleep mode. Sleep mode is a built-in circuit that will automatically shut off the main
power if the joystick is not moved in any direction for a period of time. This time factor is programmed into the controller.
To restore power and continue, push any key on the keypad.

Error Codes

The battery condition meter will flash error codes when the FLIGHT controller detects an abnormal condition is the
electrical system. All of the battery condition meter LEDs will flash a number of times quickly, then pause, then flash again.
The battery condition meter will continue to flash the error codes until the problem is fixed. The table below identifies the
individual error codes. If any of these error codes persist, contact your Quantum Rehab Specialist.

Error Code

Probable Cause

Possible Solution

1

Possible stall timeout or user error

Release the joystick

2

Battery Fault

Check the batteries and cables. Try to charge the

batteries. The batteries may need to be replaced.

3

Left motor fault

Check the left motor, connections and cabling.

4

Right Motor Fault

Check the right motor, connections and cabling.

5

Left Park Brake Fault

Check the left park brake, connections and cabling.

6

Right Park Brake Fault

Check the right park brake, connections and cabling.

7

FLIGHT Controller Module Fault

Check the communications connections and wiring.

8

FLIGHT Power Module Fault

Check the communications connections and wiring.

9

FLIGHT Communications Fault

Check the communications connections and wiring.

10

Unknown Fault

Contact your Quantum Rehab Specialist.

11

Incompatible Controller Fault

Contact your Quantum Rehab Specialist.

Advertising