) understanding the analysis report, Caution – Quincy Compressor 50093-103 User Manual

Page 51

Advertising
background image

45

!CAUTION!

Do not mix QUINSYN

®

with any other fluid.

Failure to follow these recommendations will
cause severe fluid breakdown, resulting in the
formation of heavy varnish and sludge
throughout the system. This will result in
clogged fluid separators, coolers and internal
fluid passages in the vacuum pump. Warranty
will be void.

Understanding the Analysis Report

Figure 6-1 is a representative of the fluid analysis report
returned after a sample has been submitted for analysis.
Figure 6-2 is a list of the parameters of the fluid tested.

a.) REPORT DATE - The date that the fluid was

analyzed.

b.) REPORT NUMBER - The assigned number to this

report.

c.) CUSTOMER ADDRESS - The name and address of

person that this report is being mailed to. This
information is being taken from the sample bottle as it
is received.

d.) CUSTOMER - The owner of the unit that sample came

from.

e.) VACUUM PUMP MANUFACTURER - Brand of

vacuum pump sample taken from.

f.) FLUID TYPE - This should always be QuinSyn

®

or

QuinSyn

®

F.

g.) SERIAL NUMBER - The unit serial number of the

Quincy vacuum pump the fluid sample was taken
from.

h.) MODEL NUMBER - The model number of the Quincy

vacuum pump that the fluid sample was taken from.

i.) HOURS ON FLUID - These are the actual hours that

the fluid

has been in the unit since the last fluid

change.

j.) HOURS ON MACHINE - This is the total hours on

the vacuum pump hourmeter.

k.) SAMPLE DATE - The date that the sample was taken

from the vacuum pump.

NOTE:
Items (c through k) are information provided by the
service person supplying the fluid for analysis.
Incomplete or incorrect information will affect the
report's accuracy.

l.) EVALUATION - This is a brief statement made by the

technician performing the actual fluid analysis. This
statement addresses the condition of the fluid and
filter. This statement will also note any problems that
need attention.

m.) PHYSICAL PROPERTIES RESULTS - Particle size is

measured in microns.

n.) SPECTROCHEMICAL ANALYSIS - See fluid

parameters.

Advertising