UNSCHEDULED SHUTDOWN

PROBABLE CAUSE

CORRECTION

High air discharge temperature

Correct the situation in accordance with the instruction in the
"High Discharge Air Temperature and/or High Fluid Injection
Temperature" section of this troubleshooting guide. Restart
the vacuum pump.

Thermal overload relays tripping

Correct the cause of the overloaded condition, reset the
overload relay and press the reset button

Power failure

Check the power supply to the unit.

Faulty HAT switch

Contact qualified service technician.

Loose wire connections

Check all wiring terminals for contact and tightness.

Faulty control relay

Replace relay.

THERMAL OVERLOAD RELAYS TRIPPING

PROBABLE CAUSE

CORRECTION

Excessive discharge pressure

Check exhaust piping for restrictions. Check separator
element for condition.

Low voltage

Check voltage and amperages while operating the unit at
full load and full pressure.

Loose overload connection

Tighten mounting screws on "Thermal Overload".

Phase Fault

Could be caused by low voltage, phase unbalance, or loss
of phase. This may be an intermittent problem and you may
only need to press the "Start" button to resume operation.
But if problem repeats, the power company will need to
check the incoming power.

Incorrect thermal overload relay
setting

Check motor name plate and compare to overload relay
setting.

Faulty motor

Remove and have tested at motor manufacturer repair
center.