Quincy Compressor 50093-103 User Manual

Page 67

Advertising
background image

61

VACUUM PUMP WILL NOT TIME-OUT OR SHUT DOWN WHEN UNLOADED

PROBABLE CAUSE

CORRECTION

Faulty timer

Check and replace as necessary.

Loose wire connections

Check all wiring terminals for contact and tightness.

Leaks in control lines

Check and repair leaks.

TOO RAPID CYCLING BETWEEN LOAD AND UNLOAD

PROBABLE CAUSE

CORRECTION

Too small system volume

Provide sufficient volume by adding additional piping or a
receiver to vacuum system. CAUTION: Volume adds time
to cyclic applications, be sure to consult with factory.

Leaks in control lines

Check and repair leaks.

Faulty vacuum switch

Repair or replace as necessary.

FREQUENT FLUID FILTER CLOGGING

PROBABLE CAUSE

CORRECTION

Faulty indicator

Replace indicator assembly.

Incorrect fluid filter

Use genuine Quincy replacements only.

Faulty, incorrect or inadequate air
filter

Replace filter element. Consult factory if necessary

Fluid breakdown

Correct the situation in accordance with the instructions in
"Fluid Breakdown" section of this troubleshooting guide.

System contamination

Check and clean system of all dirt, corrosion and varnish.

Inadequate circulation of cooling
air at the cooler

Check the location of the cooler to make sure that there is
no restriction to free circulation of cooling air. Also check
fins at the cooler and if dust laden, clean them with air
while the machine is not running.

Advertising