FLUID SURGES INTO VACUUM LINE AFTER SHUT-DOWN

PROBABLE CAUSE

CORRECTION

Inlet valve not closing properly

Check and repair. Install auxiliary check valve.

Excessive exhaust pressure

Check condition and resolve.

FLUID IS CLOUDY AND PUMP RUNS HOT

PROBABLE CAUSE

CORRECTION

Condensable in the fluid

Change fluid.

O-RING FITTINGS

Some QSVI models are equipped with some o-ring style fittings. These fittings are located at:

Either end of the lubricant cooler supply and return hoses.

Either end of the airend lubricant injection tube.

Either end of the air/lubricant discharge tube from the airend.

! CAUTION !

Never screw o-ring style fittings into NPT pipe fittings or ports, or
screw NPT pipe nipples or fittings into ports with SAE straight threads
intended for o-ring style fittings. Severe damage to threads, leaks or
blow out will occur.