Quatech SDS User’s Manual

Setting SNMP parameters

SDS devices with firmware revision 5.0 and higher have been
enhanced with additional Flash RAM to support SNMP. Older

hardware does not have sufficient memory to store the SNMP agent.
To determine the firmware revision level of an SDS, navigate to the
Home page in the Web-based interface (see page 45). The F/W

revision level is shown at the bottom of the Home page.

Step

Procedure

Description

‰

Preliminary
Step

Click on Network in the selection bar
and then select SNMP Setup from the

left panel.

The SNMP Setup screen shown on the
following page displays.

Figure 47 - SNMP Setup screen

Step

Procedure

Description

‰

Step 1

Enable or disable SNMP in the SDS.

¾

Select the Enable SNMP checkbox to

enable SNMP. Continue with

Step 2

.

¾

Clear the checkbox to disable SNMP.
Go to

Step 5

.

By default, SNMP is disabled and the
checkbox is cleared.

‰

Step 2

Enter the System Group information.

¾

Contact:

¾

Location:


The Contact should be the person
responsible for the operation of the SDS.
The Location could be as general as Italy

or as specific as the 3

rd

floor storage closet.

Note: The System Group Description is the
same as the SDS Descriptive Name, which
you can set on the Administration screen.

‰

Step 3

Enter the Management Host/Trap

Note: Only SDS devices with a
firmware revision level of 5.0
and above can support SNMP.

Page 52

940-0183-153

July 2005