Quatech SDS User’s Manual

Configuring the SDS using a Web interface

Step

Procedure

Description

¾

Force X4 mode

¾

Force X8 mode

Note: Forcing a change in the data rate may
cause communication problems with some

serial devices. If this is the case, change the
setting back to Auto (Recommended).

‰

Step 3b

Click on the desired Performance

Selector.

Choose balanced mode except in those

cases where the serial device cannot
tolerate the slight delays inherent in

normal TCP/IP operation.
Balanced mode offers excellent performance 
for most applications.  
Low Latency mode heavily favors 
responsiveness over throughput.

‰

Step 3c

Set the Heart Beat Time to a value from 1
to 65534 seconds. Default is 45 seconds.

Note: Use a value of 0 to disable the heartbeat
timer.

Heartbeat messages help detect when a
connection has been lost between the PC

driver and the SDS.
If you need quick notification that the
connection has been lost, set this timer to

a shorter value.
If you are more concerned about network
traffic, set this timer to a longer value.

Steps 4a through 4d apply only to RS-232/422/485 (MEI) units

‰

Step 4a

(MEI only)

Configure the serial port interface.

Click on the desired interface selector.

This series of steps only applies to MEI
units, such as the SSE-400.
If you select RS232, the RS422/485

selections will be grayed out. Continue
with

Step 5

.

‰

Step 4b

(MEI only)

Click on the desired duplex mode selector. Select Full Duplex to always enable

transmit and receive drivers.
Select
Half Rx to only enable the

transmit drivers when the SDS is

transmitting; receivers will always be
enabled.

Select Half Rx Tog to disable receivers
and enable the transmit drivers only

when the SDS is transmitting.

‰

Step 4c

(MEI only)

Click on the desired connector setup.

Select Loopback All to internally loopback

RTS and CTS in the SDS. AuxIn and
AuxOut are looped at the connector.

Select Modem Control to send RTS on

the AuxOut signal and to receive CTS on
the AuxIn signal.

‰

Step 4d

(MEI only)

Select 2- or 4-wire communication.

Select 2-wire to use the transmit pair for

both transmit and receive in RS-422/485.

Select 4-wire to use a separate pair of wires
for transmit and receive in RS-422/485.

July 2005

940-0183-153