VII. g - ADJUSTING THERMOSTAT SET POINT HIGH:

This parameter sets the high point of the desired cabinet temperature range. Typically, freezers will range from -3° F to 0°
F (-19° C to –18° C) and refrigerators will range from 36° F to 40° F (2° C to 4° C) for this parameter setting. This parameter
is preset at the factory and does not have to be adjusted unless the customer chooses to do so. Note: Set Point Low and
Set Point High cannot be set to the same temperature. There must be at least 1-2 degree difference between the two set-
tings.

Follow the instructions to enter the customer access code on page 8. When the control

display reads Thermostat Set Point High. Press the set button .

Use the arrow keys to adjust the temperature to your desired setting.

When the display shows the temperature you want press the set button .

The display will then read Thermostat Set Point High.

You can use the up or down arrow keys to scroll to the next parameter .

or press the alarm cancel button to exit

.

VII. MICROPROCESSOR CONTROL (continued)

-9-

Listed below are the available parameters in the order they appear, using the down arrow key on the controller. You can

use either the up or down arrow keys to scroll through the options.

Thermostat Set Point High

Defrost Lockout 3

Thermostat Set Point Low

Defrost Lockout 4

Temperature Scale

Dew Point Compensation Factor

Time (24-hour clock)

Room Temperature Offset

Date (month-day-year)

Audible Alarm Style

Daylight Savings

Cabinet Air Sensor Temp

Start Manual Defrost

Evaporator Coil Sensor Temp

Defrost Lockout 1

Discharge Line Sen

sor

Temp

Defrost Lockout 2

VII. f - SERVICE PARAMETERS: